Siemens has upgraded its Sitop PSU8600 power supply system with the addition of new supplementary modules to transform it into an uninterruptible direct current (DC) power supply. To achieve this, the new DC UPS module UPS8600 uses the energy stored in BAT8600 battery modules to keep the system up and running in the event of a power failure, and it extends the previous bridging times enabled by the buffer modules from just minutes to hours. The PSU8600 has up to 36 outputs capable of being adjusted between 4 and 28 volts, and all of these can be buffered in the event of a power failure. To maximize buffering time for important loads, it is also possible to selectively shut down certain outputs. The Sitop PSU8600 is particularly suitable for use in applications which place stringent demands on reliability and simple integration, such as the automotive, food or pharmaceutical industries, and in the field of plant and special-purpose machinery building. The enhanced availability with the new UPS8600 makes the power supply ideally suited also for process applications such as in the chemical, oil or gas industry.

The DC UPS module can be simply integrated into the system network of the Sitop PSU8600 using the System Clip Link. The battery module is installed by means of wall mounting outside the network and connected to the UPS8600 over a plus and minus wire and the two wires of the Energy Storage Link. This allows the system to automatically detect the battery type and diagnose the battery charge status. The smart battery management system permits temperature-led charging, which helps to extend the service life of the battery. The battery modules are fitted with lead (PB) or lithium iron phosphate (LiFePO4) batteries with a capacity of 380 Wh (Watt hours) and 264 Wh respectively. Users are able to connect up to five BAT8600 battery modules to one UPS8600 to further increase the mains power failure bridging time. The BAT8600 battery module using lithium technology offers a particularly long service life, even at higher ambient temperatures.

The DC UPS is able to communicate with practically any automation system at any time through the base PSU8600 module, which has Profinet and OPC UA capability. Users can respond directly to messages and diagnostic information about the operating mode (mains or buffer operation), charge status, buffer readiness, or the need to change a battery. Integration in the network allows several PCs to be safely powered down with the UPS8600. Engineering takes place with the utmost convenience in the TIA Portal, while diagnostic functions use WinCC Faceplates or the Simatic PCS 7 Library. For open integration over Ethernet or OPC UA, new software is currently in preparation which enables convenient system-independent engineering, operation and observation.

For further information on Siemens at the Hannover Messe 2018, please see www.siemens.com/press/hm18 and www.siemens.com/hannovermesse.

, Siemens

News material on the Site is copyright and belongs to the Company or to its third party news provider, and all rights are reserved. Any User who accesses such material may do so only for its own personal use, and the use of such material is at the sole risk of the User. Redistribution or other commercial exploitation of such news material is expressly prohibited. Where such news material is provided by a third party, each User agrees to observe and be bound by the specific terms of use applying to such news material. We do not represent or endorse the accuracy or reliability of any of the info contained in any news or external websites referred to in the news.

Should the content or the design of these sites violate third parties rights or legal prescriptions, we kindly ask you to send us a respective message without invoice or cost. We guarantee that passages where the claim is considered as justified will be removed immediately, without any necessity to involve any lawyer into this issue. We will reject any claim caused by submission of a honorary note in this regard without any prior contact and confirmation of the issueby us and we reserve the right ssue counter claim ourselves because of violation of aforesaid conditions.



Info Grid

Glass studies

Updated worldwide glass study 2019

plants.glassglobal.com

Updated hollow glass study 2019

Request more information

Updated float glass study 2019

Request more information

Company Profile



Updated worldwide glass market study 2019 available now for flat, container glass and tableware

We have updated our international studies on flat glass, container glass and tableware for 2019.

This unique software provides a global overview about glass producers and technical details. Easy to use and clear tables summarize information and data about glass makers such as: Glass types: flat glass, container glass, tableware, production capacities in regions and countries, number of furnaces, furnace types, year of construction, glass types and sub-types, products, project information, special news and downloads.

Further databases supplying demoscopic data and import and export data complete the market survey. Based on these data, prepare individual country profiles with information about local production capacities, local market sizes and expected demand in the future.

Request your offer via plants.glassglobal.com.

Updated Hollow glass study 2019

X

Updated Float glass study 2019

X